G-03—Natural gas meters and ancillary devices qualified for a lengthened initial reverification period

Category: Gas
Issue date: 2024-03-15
Effective date: 2024-03-15
Revision number: 10
Supersedes: G-03 (rev.9)


Table of contents


1.0 Purpose

This bulletin provides an official record of the natural gas meters and ancillary devices that qualify for a lengthened initial reverification period pursuant to Measurement Canada specifications S-EG-01 and

S-S-05, and of the meters no longer qualify for a lengthened initial reverification period.

2.0 References

3.0 Abbreviations

EVC
electronic volume conversion
IRP
initial reverification period
P
pressure
PT
pressure and temperature
PTZ
pressure, temperature and supercompressibility
T
temperature

4.0 Lengthened initial reverification periods

Lengthened IRPs and associated subsequent reverification periods are established in bulletin G-18.

5.0 Gas meters and ancillary devices qualifying for an unconditionally lengthened initial reverification period

Table 1—Gas meters and ancillary devices qualifying for an unconditionally lengthened IRP
Approval
no.
Manufacturer Model(s) Device type and capacity Applicability
AG-0355 Elster American Meter AC-250
ACM-250
Diaphragm meter
5.5 m³/h (air) 195 ft³/h (air)
All meters granted or still within an IRP on or after January 1, 2009.
AG-0373 Sensus Metering Systems R-275
MR-8
Diaphragm meter
5 m3/h (air) 175 ft³/h (air)
All meters granted or still within an IRP on or after January 1, 2009.
AG-0393 Itron METRIS 250
METRIS M250
Diaphragm meter 5.5 m³/h (air) 195 ft³/h (air) All meters granted or still within an IRP on or after January 1, 2009.
AG-0424 Romet Limited ECM2 (with firmware versions L and K) EVC device (T only) All meters granted or still within an IRP on or after January 1, 2012.
AG-0452 Honeywell (Mercury Instruments) Mini-AT Mini-AT TOC EVC device (P, PT and PTZ) All meters granted or still within an IRP on or after January 1, 2012.
AG-0479C Galvanic Applied Sciences Inc. GASMicro IM-P GASMicro IM-P-T EVC device (P, PT and PTZ) All meters granted or still within an IRP on or after January 1, 2012.
AG-0481 Honeywell (Mercury Instruments) Mini-Max Mini-Max AT Mini-Max ATX EVC device (T, P, PT and PTZ) All meters granted or still within an IRP on or after January 1, 2012.
AG-0490 Dresser Natural Gas Solutions North America, LLC 197 (T+log) 201 (T+log) EVC device (T only) All meters granted or still within an IRP on or after January 1, 2012.
AG-0514 Sensus Metering Systems Sonix 25 (880) Ultrasonic meter 25 m3/h 880 ft3/h All meters granted or still within an IRP on or after January 1, 2016.
AG-0562 Honeywell (Mercury Instruments) TCI EVC device (T only) All meters granted or still within an IRP on or after January 1, 2017.
AG-0593 Romet Limited AdEM-T EVC device (T only) All meters granted an IRP on or after January 1, 2011.
AG-0611 Dresser Natural Gas Solutions North America, LLC D800 EVC moduleFootnote 1 (with firmware version 1.74) EVC device (T only) All meters granted an IRP on or after January 1, 2015.

5.1 Granting an unconditionally lengthened initial reverification period to qualifying meters

An unconditionally lengthened IRP may be granted to qualifying gas meters and ancillary devices listed in Table 1:

  1. if they were initially verified on or after the applicability date indicated in Table 1, or
  2. if their IRP still applies as of the applicability date and they were not subject to calibration adjustments or component exchanges during that period, in which case it is granted retroactively.

5.2 Granting a subsequent reverification period to qualifying meters

5.2.1 Exception

The subsequent reverification period associated with a lengthened IRP may not be granted retroactively to qualifying gas meters and ancillary devices listed in Table 1 if a subsequent reverification period still applies on or after the applicability date indicated in Table 1.

5.2.2 Reserviced and reverified gas meters and ancillary devices

The subsequent reverification period associated with a lengthened IRP may be granted to qualifying gas meters and ancillary devices listed in Table 1 that are reserviced and reverified by 100% inspection or acceptance sampling on or after the applicability date indicated in Table 1.

5.2.3 Renewed and reverified gas meters and ancillary devices

A subsequent reverification period equal in duration to a lengthened IRP may be granted to qualifying gas meters and ancillary devices listed in Table 1 that are renewed and reverified on or after the applicability date indicated in Table 1.

5.2.4 Gas meters and ancillary devices reverified by compliance sampling

Where qualifying gas meters and ancillary devices listed in Table 1 are reverified by compliance sampling on or after the applicability date indicated in Table 1, the available reverification period extensions are based on the applicable lengthened IRP.

6.0 Gas meters and ancillary devices qualifying for a conditionally lengthened initial reverification period

Table 2—Gas meters and ancillary devices qualifying for a conditionally lengthened IRP
Approval
no.
Manufacturer Model(s) Device type and capacity Applicability
AG-0606 Romet Limited AdEM-PTZ (with firmware versions C07XZ004, D05XZ004 and D05XZ064) EVC device (PTZ)

All meters whose IRP was granted on or after January 1, 2018. Conditional on successful completion of interim sampling in accordance with S-S-05 by June 30, 2024.

AG-0642 Itron Intelis 250 Ultrasonic meter

All meters whose IRP was granted on or after January 1, 2022.
Conditional on successful completion of interim sampling in accordance with S-S-05 by June 30, 2028.

6.1 Granting a conditionally lengthened initial reverification period

A conditionally lengthened IRP may be granted to qualifying gas meters and ancillary devices initially verified on or after the applicability date indicated in Table 2, subject to the following conditions:

  1. Interim sampling in accordance with specification S-S-05 is successfully completed by the date given in Table 2.
  2. Full compliance with the requirements of bulletin GEN-27 for recording IRPs is achieved.

6.2 Conditions of a lengthened initial reverification period satisfied

Gas meters and ancillary devices listed in Table 2 that satisfy the conditions under section 6.1 will be moved to Table 1 and the conditions of the lengthened IRP will be removed. As required by bulletin GEN‑27, affected meter owners will be required to update their meter records to reflect the change from a conditionally lengthened IRP to an unconditionally lengthened IRP.

6.3 Conditions of a lengthened initial reverification period not satisfied

Gas meters and ancillary devices listed in Table 2 that do not satisfy the conditions under section 6.1 will be moved to Table 3 and their conditionally lengthened IRP will be revoked.

7.0 Gas meters and ancillary devices no longer qualifying for a lengthened initial reverification period

Table 3—Gas meters and ancillary devices no longer qualifying for a lengthened IRP
Approval
no.
Manufacturer Model(s) Device type and capacity Applicability
AG-0355 Elster American Meter AC-250R
ACM-250R
Diaphragm meter 5.5 m³/h (air) 195 ft³/h (air) Lengthened IRP revoked. IRP amended to seven years for all meters granted an IRP on or after January 1, 2002.

7.1 Revocation of unconditionally lengthened initial reverification periods

Where performance results at preceding, interim or future inspections are found to be unsatisfactory, gas meters and ancillary devices listed in Table 1 may be moved to Table 3 and the unconditionally lengthened IRPs may be revoked.

8.0 Revisions

The purpose of revision 10 was to add an ultrasonic meter to Table 2.

The purpose of revision 9 was to:

  • move an EVC device from Table 2 to Table 1;
  • add an abbreviation section;
  • update the format of the tables.

The purpose of revision 8 was to:

  • move an EVC device from Table 2 to Table 1;
  • add an EVC device to Table 2.

The purpose of revision 7 was to:

  • reformat the document and adhere to plain language rules;
  • add an electronic volume conversion device to Table 1;
  • add an electronic volume conversion device to Table 2;
  • correct the applicability date in Table 1 for the Sensus Sonix 25 meter from 2010 to 2016.

The purpose of revision 6 was to:

  • add an electronic volume conversion device to Table 2;
  • add requirements for meters qualifying for a conditionally lengthened initial reverification period;
  • make additional minor editorial changes.

The purpose of revision 5 was to:

  • add ultrasonic meters that have qualified for a lengthened initial reverification period;
  • make editorial changes to subsection 5.2;
  • include ultrasonic meters in item 5.3(a).

The purpose of revision 4 was to:

  • add tables 2 and 3;
  • move certain Elster American Meter diaphragm meter models from Table 1 to Table 3 and communicate the suspension of their qualification for a lengthened initial reverification period.

The purpose of revision 3 was to replace the footnote in Table 1 with more detailed policy requirements for granting lengthened initial, and associated subsequent, reverification periods to qualified meters.

The purpose of revision 2 was to add electronic volume conversion devices with pressure or pressure and temperature conversion functions that have qualified for a lengthened initial reverification period.

The purpose of revision 1 was to add temperature only electronic volume conversion devices that have qualified for a lengthened initial reverification period.