E-28—Qualification of Electricity Meters for Lengthened Initial Reverification Period of 10 years

E-28—Qualification of Electricity Meters for Lengthened Initial Reverification Period of 10 years (PDF, 50 KB, 12 pages)


Category: ELECTRICITY
Bulletin: E-28 (rev. 7)
Document(s): S-EG-01, S-S-05, E-26
Issue Date: 2012-01-01
Effective Date: 2012-01-01
Supersedes: E-28 (rev. 6)


Table of Contents


1.0 Purpose & Scope

The purpose of this bulletin is to officially communicate the electronic electricity meters that have been conditionally and unconditionally qualified for a 10-year initial reverification period pursuant to Measurement Canada specifications S-EG-01 and S-S-05, and to communicate those meters that no longer qualify for a lengthened initial reverification period.

2.0 References

2.1 Electricity and Gas Inspection Act (R.S. 1985, c. E-4), s. 12.

2.2 Electricity and Gas Inspection Regulations (SOR/86-131), ss. 3(1), s. 19.

2.3 Specification S-EG-01, Electricity and Gas Meter Pattern Approval Applications - Quality and Measurement Reliability Information Requirements in Support of a Lengthened Initial Reverification Period

2.4 Specification S-S-05, Performance Requirements Applicable to Meters Granted a Conditionally Lengthened Initial Reverification Period under S-EG-01

3.0 Initial Reverification Period Tables

Table 1 - Electricity Meters Qualified for an Unconditional 10 year Initial Reverification Period
Manufacturer Model(s) Approval No. Rating/Configuration Applicability
Itron
  • C1S (D, T, L and R model designations)
  • CN1S (D, T, L and R model designations)
  • CN1SX
  • C1SX
AE-0920
  • 1 element, 2 wire, single phase, 120 volts, 240 volt, 0.2-20, 0.25-100, 1.0-100 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 240 volts, 0.5-200, 2.0-200 amperes, 60 Hz
  • 2 element, 3 wire, network, 120 volts, 0.5-200, 2.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Itron
  • Sentinel
AE-1132
  • 1 element, 2 wire, single phase, 120 to 480 volts, 0.2-20 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120 to 480 volts, 0.5-200 amperes, 60 Hz
  • 2 element, 3 wire, network and single phase, 120 to 480 volts, 0.5-200 amperes, 60 Hz
  • 2 element, 3 wire, delta, 120 to 480 volts, 0.05-20, 0.5-200 amperes, 60 Hz
  • 2.5 element, 4 wire, Wye or delta, 120 to 480 volts, 0.2-20, 0.5-200 amperes, 60 Hz
  • 3.0 element, 4 wire, Wye or delta, 120 to 480 volts, 0.2-20, 0.375-150, 0.5-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

General Electric Co.
  • KV2c
  • KV2c+
  • KV2e
  • KV2n
AE-1059
  • 1 element, 2 wire, single phase, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 element, 3 wire, single phase, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, 120 to 480, 600 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, delta, 120 to 480, 600 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2.5 elements, 4 wire, Wye, 120 to 480 volts, 0.2-20 amperes, 60 Hz
  • 3 elements, 4 wire, Wye or delta, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

General Electric Co.
  • I-210
AE-1342
  • 2 wire, single phase, 120, 240 volts, 0.2-20, 1.0-100 amperes, 60 Hz
  • 3 wire, single phase, 240 volts, 0.2-20, 1.0-100, 2.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Elster Metering
  • ALPHA 1
  • A1*
  • A1D*
  • A1T*

*(L, A, Q, +) / (P, M, Z, S, A)
Only model designations with '+' in the type designation.

AE-0541
  • 2 elements, 3 wire, network. 96 to 528 volts, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, delta, 96 to 528 volts, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2.5 elements, 4 wire, Wye, 96 to 528 volts, 0.1-20, 1.0 -200 amperes, 60 Hz
  • 3 elements, 4 wire, Wye or delta, 96 to 528 volts, 0.1-20, 1.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Elster Metering
  • ALPHA 1
  • A1K*
  • A1R*

*(L, A, Q, +) / (P, M, Z, S, A)
Only model designations with '+' in the type designation.

AE-0580
  • 2 elements, 3 wire, network, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, delta, 96 to 528 volts 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz
  • 2 5 elements, 4 wire, Wye, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz
  • 3 elements, 4 wire, Wye or delta, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Elster Metering
  • ALPHA 1
  • A1*
  • A1D*
  • A1T*
  • A1K*
  • A1R*

*(L, A, Q, +) / (P, M, Z, S, A)
Only model designations with '+' in the type designation.

AE-0601
  • 1 element, 2 wire, single phase, 120 to 480, 240 volts, 0.1-20, 1.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120 to 480, 240 volts, 0.1-20, 1.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Elster Metering
  • ALPHA 3
  • A3K
  • A3D
  • A3T
  • A3R

/(Q, L, N, C, A) Model designations

AE-1168
  • 1.5 elements, 3 wire, single phase, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, delta, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2.5 elements, 4 wire, Wye, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-200 amperes, 60 Hz
  • 3 elements, 4 wire, Wye, 96 to 528 volts, 0.1-10, 0.1-20, 1.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Elster Metering
  • REX
  • R1
  • RS
  • R1SD
AE-1320
  • 1 element, 2 wire, single phase, 120 to 240 volts, 0.1-20, 1.0-200 amperes, 60 Hz
  • 1.5 elements, 3 wire, single phase, 120 to 240 volts, 0.1-20, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 120 to 240 volts, 0.1-20, 1.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

Landis + Gyr Inc. Focus ALF AE-1356
  • 1 element, 2 wire, single phase, 120, 240 volts, 0.1-10, 2.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120, 240 volts, 0.1-10, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 120 volts, 2.0-200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.

TRIACTA Power Technologies POWERHAWK 6320 AE-1434
  • 2 elements, 3 wire, single phase, network, 120 volts, 0.05 to 5 amperes, 2 to 200 amperes, 60 Hz
  • 3 elements, 4 wires Wye, 120 volts, 0.05 to 5 amperes, 2 to 200 amperes, 60 Hz

Unconditional 10 year initial reverification period for all meters.


Table 2 - Electricity Meters Qualified for a Conditional 10 year Initial Reverification Period
Manufacturer Model(s) Approval No. Rating/Configuration Applicability
(Electronic electricity meters qualified for a conditional 10 year initial reverification period which are subject to additional testing prior to the end of the six year initial reverification period)
Landis + Gyr Inc.
  • RXS4e
  • RXRS4e
  • AXS4e
  • AXLS4e
  • AXRS4e
AE-0764
  • 1 element, 2 wire, single phase, 120 to 480 volts, 0.1-10, 0.2-20, 2.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120 to 480 volts, 0.1-10, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network or delta, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2.5 elements, 4 wire, Wye or delta, 120 to 480 volts, 0.2-20 amperes, 60 Hz
  • 3 element, 4 wire, Wye or delta, 120 to 480 volts, 0.2-20, 2.0-200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2007.

Sampling in accordance to S-S-05 required prior to June 2013

Landis + Gyr Inc.
  • Focus II ALF
AE-1559
  • 1 element, 2 wire, single phase, 120, 240 volts, 0.1-10, 0.2-20, 2.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120, 240 volts, 0.1-10, 2.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 120 volts, 2.0-200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2008.

Sampling in accordance to S-S-05 required prior to June 2014.

Elster Metering
  • REX2
  • R2S
  • R2SD
  • gREX
AE-1579
  • 1 element, 2 wire, single phase, 120, 240 volts, 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz
  • 1.5 elements, 3 wire, single phase, 120, 240 volts, 0.1-10, 0.1-20, 1.0-100, 1.0-200 amperes, 60 Hz
  • 2 elements, 3 wire, network, 120 volts, 1.0-200 amperes, 60 Hz
  • 2 element, 3 wire, delta, 600 volts, 1.0-200 amperes, 60 Hz

gREX:

  • 1 element, 2 wire, single phase, 120, 240 volts, 1.0-100 amperes, 60 Hz
  • 1.5 elements, 3 wire, single phase, 240 volts, 1.0-100 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2008.

Sampling in accordance to S-S-05 required prior to June 2014.

Itron
  • CP1S (D, T, L and R model designations)
AE-1466
  • 3 element, 4 wire, Wye or delta, 120 to 480 volts, 0.02-20, 0.5 -200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2006.

Sampling in accordance to S-S-05 required prior to June 2012.

Itron
  • CVSO (D and R model designations)
AE-1498
  • 1.5 element, 3 wire, single phase, 240 volts, 0.5-200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2007.

Sampling in accordance to S-S-05 required prior to June 2013.

General Electric Co.
  • I-210+
  • I-210+n
AE-1517
  • 2 wire, single phase, 120 volts, 0.2-20, 1.0-100 amperes, 60 Hz
  • 3 wire, single phase, 240 volts, 0.2-20, 2.0-200 amperes, 60 Hz
  • 2 element, 3 wire, network, 120 volts, 2.0-200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2007.

Sampling in accordance to S-S-05 required prior to June 2013.

Sensus Metering Systems Inc
  • iSA2 with Flexnet 530-X
AE-1611
  • 2 wire, single phase, 120, 240 volts, 0.2-20, 1.0-200 amperes, 60 Hz
  • 1.5 element, 3 wire, single phase, 120, 240 volts, 0.2-20, 1-200 amperes, 60 Hz
  • 2 element, 3 wire, network, 120, 240 volts, 1-200 amperes, 60 Hz

Conditional 10 year initial reverification period applicable to meters verified on or after January 1st, 2009.

Sampling in accordance to S-S-05 required prior to June 2015.


Table 3 - Electronic Electricity Meters that no longer Qualify for the Conditional 10 Year Initial Reverification Period
Manufacturer Model(s) Approval No. Rating/Configuration Applicability
(Electronic electricity meters that no longer qualify for the conditional 10 year initial reverification period or have not completed the sampling as required in accordance with S-S-05)
Itron
  • Q1000
AE-0828
  • 2 element, 3 wire, delta, 69, 120 volts, 0.05 -20 amperes, 60 Hz
  • 2.5 element, 4 wire, Wye or delta, 69, 120 volts, 0.05 -20 amperes, 60 Hz
  • 3 element, 4 wire, Wye or delta, 69, 120 volts, 0.05 -20 amperes, 60 Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1st, 2003.

Power Measurement Ltd.
  • ION 8300
  • 8400
  • 8500
  • 8600
AE-0924
  • 2 element, 3 wire, delta, 120 to 480 volts (L-L), 0.1-20, 0.05-20 amperes, 60 Hz
  • 2.5 element, 4 wire, Wye, 69 to 277 volts (L-N), 0.1-20, 0.05-20 amperes, 60 Hz
  • 3 element, 4 wire, Wye, 69 to 277 volts (L-N), 0.1-20, 0.05-20 amperes, 60 Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1st, 2003.

Power Measurement Ltd.
  • ION 6200
  • Siemens 9200
AE-1143
  • 2 element, 3 wire, single phase, 69 to 347 volts (L-N), 0.1-10 amperes, 60 Hz
  • 2 element, 3 wire, delta, 120 to 600 volts (L-L), 0.1-10 amperes, 60 Hz
  • 3 element, 4 wire, Wye, 69 to 347 volts (L-N), 0.1-10 amperes, 60 Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1st, 2003.

Power Measurement Ltd.
  • ION 7550
  • 7650
  • Siemens 9510
  • 9610
AE-1484
  • 3 element, 4 wire, Wye, 57 to 347 volts (L-N), 0.05-20 amperes, 60Hz
  • 2 element, 3 wire, delta, 120 to 600 volts (L-L), 0.05-20 amperes, 60Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1st, 2003.

Power Measurement Ltd
  • ION 8600
AE-1535
  • 2 element, 3 wire, delta, 120 volts (L-L), 0.2-20 amperes, 25Hz
  • 3 element, 4 wire, Wye, 120 volts (L-L), 0.2-20 amperes, 25Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1st, 2003.

Sensus Metering Systems Inc
  • iCon
  • iCon Flexnet 530-X
  • iCon RadioRead 530-E MXU
AE-1145
  • Single phase, 3 wire, 120, 240 volts, 1-200 amperes, 60 Hz
  • 2 element, 3 wire, network, 120, 240 volts, 1-200 amperes, 60 Hz

Conditional 10 year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after Jan. 1, 2005

4.0 Revision

4.1 The purpose of revision 2 was to clarify and reflect the change in references from Measurement Canada provisional specification PS-E-11 to specification S-EG-01. Revision 2 amends the scope to include meters that have been conditionally and unconditionally qualified to receive a 10 year initial reverification period, and meters that no longer qualify for a lengthened initial reverification period.

4.2 The purpose of revision 3 was to add AE-1320 to table 1 and include additional configurations for AE-1611 in table 2.

4.3 The purpose of revision 4 was to add additional ratings and or configurations for AE-1611 and AE-0764 in table 2.

4.4 The purpose of revision 5 was to add additional ratings and or configurations for the meters under AE-1517 and AE-1579 in table 2. Also, meters under AE-1145 are included in table 3 to indicate a suspension of the lengthened initial reverification period until sampling pursuant to S-S-05 is completed.

4.5 The purpose of revision 6 was to add AE-1356 to table 1.

4.6 The purpose of revision 7 is to add AE-1434 to table 1.

5.0 Additional Information

For additional information regarding this bulletin, please contact the Senior Program Officer responsible for electricity measurement.

David Flieler
Senior Program Officer
Measurement Canada